Magnetic Check Valve

Magnetic Check Valve

share
  • Detail
  • Parameters


Introduction

  • Diaphragm check valve is designed with full seal valve body, filter screen, PTFE seal, pilot device inside, spring reset, thread seal at valve seat and PTFE.

  • Diaphragm check valve is widely used in compressor exhaust line. And it is used to prevent liquid refrigerant from backflow to compressor.

Feature

  • Full seal valve body design;

  • Zero leakage in backflow.

  • Filtrate screen inside, capable of filtration and stop.

  • Low resistance and high flow rate.

  • Straight in line, small size, light weight, and no limitation in installation;

  • Applicable to all refrigerants.

  • ODE connection, exchangeable. ODF tubing size 1/4” ~ 3-1/8”

  • Media temperature-40℃~+120℃  

Technical Parameter

        PN

Tube size

(inch

OD(mm)

Max operation

pressure

(MPa)

Liquid refrigrant

(KW

Screen

SSP-H007/6

1/4

22

5.5

6.8

40

SSP-H007/10

3/8

22

5.5

14.2

40

SSP-H007/12

1/2

28.6

5.2

38.2

40

SSP-H007/16

5/8

28.6

5.2

42.6

40

SSP-H007/19

3/4

41

4.1

79.7

40

SSP-H007/22

7/8

41

4.1

108.5

40

SSP-H007/28

1-1/8

54

4

188.5

40

SSP-H007/35

1-3/8

54

4

232.8

40

SSP-H007/42

1-5/8

79.4

3

397.7

40

SSP-H007/54

2-1/8

79.4

3

691.1

40

SSP-H007/67

2-5/8

105

3

927.3

40

SSP-H007/79

3-1/8

105

3

1262.5

40


Code
SSP-H007
Type
Check Valve
Brand
Sensor Plus